Hot Swap Rectifiers
150 Watt Rectifiers
   ULM-100
600 Watt Rectifiers 1.8kW
1000-2000 Watt
Rectifiers 6kW
2000 Watt Rectifiers, 14kW
Rackmount Rectifiers
Power Modules
Integrated w/ built-in battery
Power Function Manager
ULM-100
DC-DC Converters
Rackmount
Mobile Mount
DC-AC Inverters
Rackmount
Mobile Mount
Power Distribution
Circuit Breaker
Fuse
DST-FB
Power Distribution System
Battery Chargers
Wall Mount
12, 24, 32 V; 8-95 Amps
Wall Mount Modular
12, 24 V; 67-100 Amps
Mobile Mount
12, 24 V; 8-35 Amps
Power Plants
DC Power Plants
Rackmount Power
Accessories
Rack Accessories
Trays & Shelves
Remote Monitoring
Site Power Monitor
Site Monitor & Control
Batteries & Accessories
Battery Modules
Batteries
Battery Trays & Shelves
Integrators & Isolators
Instruments/Analyzers
Automatic Power Selector
Power Supplies
Mobile Mount
With built-in battery
Enclosure Power System
Pole or Wall Mount
Site Power System
RR Site Power System
Low Voltage Disconnects
Rackmount
Wall Mount
Disconnect Timer
Mobile DC UPS
StartGuard & Nav-Pac

Mobile Data Power System

DC Power Conditioners
12 & 24 Volt Stabilizers
Noise Filters
Accessories
Digital Meters
Communication
Electrical Installation
Phone Coms
Paging Speakers
Waterproof radio covers

Click Here To Download
A PDF Version Of Our
Product Catalog

Newmar © 2010

Commander Power System

NCPS6000 Power System

Incredible Functionality, Flexibility, and Scalability in a 5 RU, 1.0 to 14.0 Kw DC Power System

• 19", 5U rackmount shelf with integrated power distribution
• 90-250 VAC input, Power Factor Corrected
• 7 power bays accept 1000 or 2000 watt modular rectifiers
• 259 amp, 14,000 watt total max. output capacity, (222 Amp, 2,000 Watt, N+1) @ - 54 VDC
• Output temperature compensated for precise battery charging
• 18 DC circuit breaker distribution capacity, with tripped breaker alarm, 63 amp max. circuit
   breaker rating
• Master disconnect breakers for four battery banks, with tripped breaker alarm
• Controller with digital display of system parameters with TCP/IP interface and SNMP
   monitoring/logging
• Alarm contacts monitor major system functions
• Low voltage disconnect built in
• Easily configures to meet site power requirements

Complete system design and integration by Newmar to your application parameters: Rectifier configuration, installation of distribution circuit breakers, and configuration of alarms and monitors. Assembly in a relay rack with batteries and wiring also available. Let us submit a proposal on your next project.

System Power Configurations @ 48V*
Watts Per Rectifier # of Rectifiers Installed
1 2 3 4 5 6 7
2000 37A
(2000W)
74A
(4000W)
111A
(6000W)
148A
(8,000W)
185A
(10,000W)
222A
(12,000W)
259A
(14,000W)
* @ 230 VAC input, 2Kw: derate 41% @ 110 VAC input; 1Kw: derate 33% @ 110 VAC input

AC Input
Nominal: 230V
Voltage Range: 90-300V (derate @ 115 input)
Wiring Options:
    1) Single 208-240VAC, 3 phase, 4 wire WYE ('Y') input or
    2) 3 x separate 208-240VAC, 2 wire inputs
Frequency Range: 45-65 Hz
Power Factor: >0.99
Efficiency: >94% (from 30-95% output power)

DC Output
Voltage:
-48 volt
Output Ratings:
Constant power output from 48V to 58V
Nominal Voltage: 48V
Rated Voltage: 58V

Power:
Rated maximum System Output Power: 14,000W @ -48V
Polarity: Positive Earth (or specify)

Individual Rectifier Power:
(48 volt)   2000 watt
Amperage @ 230 vac in    37
Amperage @ 115 vac in    21

DC Distribution:
Load: 18 breaker positon capacity, available amperages (specify) 6A, 10A, 15A, 20A, 30A and 63A tripped breaker alarm
Battery: 4 x 100A battery circuit breakers.
Breaker Fail Detection: Electronic fail detection on both load and battery breakers
Low Voltage Battery Disconnect: 300A battery LVD installed standard, with disconnect alarm

Monitoring & Control:
Monitors all power system conditions including DC voltage, rectifier current, battery current, battery temperature, and distribution failure. Visual notification of alarm conditions by LED's and a 4 line x 16 character alpha numeric display mounted on the front panel, with remote notification being enabled by relay contacts, RS232 or TCP/IP (using SNMP). It has a built-in web based configurator allowing setup of system parameters using a web browser and utilizes a USB communications port which allows for local monitoring of system operations as well as easy downloading of configuration files for multiple site installations.

General System

Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current reduction, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over Voltage: Adjustable limit.
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
Input Fuses: In phase and neutral.

Technical Characteristics:
Noise: Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <1mV rms psophometric
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <100mV peak to peak
Isolation: Input to Output: 4000V DC.
Input to Chassis: 3500V DC (VDR to chassis removed)
Output to Chassis: 2100V DC
Regulation: Line = ±0.1%, Load = ±0.5% (no load to full load)

Mechanical:
Shelf: Dimensions / 19" W x 8.75" H x 15.35" D /
Weight: 35.15 Lbs. (excluding rectifier modules)
Rectifers: Dimensions / 4.25" W x 2.75" W x 11.1" D /
Weight: 3.15 Lbs
Cooling: Forced cooled

Environmental
Ambient Temperature: Nominal: 25+/-5º C
Range: -10º C to +70º C (maximum output power is derated above +50º C)
Humidity: 5-95% RH (non-condensing)
Altitude: <8,202 ft., De-rate maximum ambient temperature by 4º C per 3,280 ft. above sea level.

Compliances:
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Freq: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker & Fluctuation: EN61000-3-3
Other: CE & RoHS compliant