Visit our Product Selection Guide for help choosing the correct product and model for your application.
Hot Swap Rectifiers
150 Watt Rectifiers
550 Watt Rectifiers
1600 Watt Rectifiers, 48V
Rackmount Rectifiers
Power Modules
Integrated w/ built-in battery
Power Function Manager
DC-DC Converters
Rackmount
Mobile Mount
DC-AC Inverters
Rackmount
Mobile Mount
Power Distribution
Circuit Breaker
Fuse
Power Distribution System
Battery Chargers
Wall Mount
12, 24, 32 V; 8-95 Amps
Wall Mount Modular
12, 24 V; 67-100 Amps
Mobile Mount
12, 24 V; 8-35 Amps
Power Plants
DC Power Plants
Rack Accessories
Trays & Shelves
Batteries & Accessories
Battery Modules
Integrators & Isolators
Instruments/Analyzers
Automatic Power Selector
Power Supplies
Mobile Mount
With built-in battery
Enclosure Power Supply
Pole or Wall Mount
Low Voltage Disconnects
Rackmount
Wall Mount
DC Power Conditioners
StartGuard & Nav-Pac

Noise Filters

Voltage Stabilizing Converters

DC Power Stabilizers
12 & 24 Volt Stabilizers
Accessories
Installation
Electrical Installation
Phone Coms
Paging Speakers
Waterproof radio covers
DC-DC Converters Isolated & ISP Series

Newmar’s Isolated Series converters that provide input/output isolation, allowing use of negative ground electronics on off-highway vehicles which are usually employ positive ground battery systems. The ISP DC-DC Converters provide input/output isolation along with protection against line transients and voltage spikes.

Isolated Series
As well as voltage conversion, this series provides input/output isolation, allowing use of negative ground electronics on off-highway vehicles which typically employ positive ground battery systems. May also be used as a Voltage Stabilizer for sensitive equipment.

ISP Series
offer the benefits of an isolated converter (above) plus protection against line transients and voltage spikes typically caused by large DC motors and switching transients often encountered on fork lifts, locomotives and light rail. A special circuit clamps input spikes to a safe level, protecting both the converter and the powered equipment.

This product series is further enhanced with extra rugged construction of case and internal components for severe vibration applications.


Features:
Isolated & ISP Series
• Reverse polarity protection
• Input fuse
• Output fuse
• Current limiting, short circuit proof output
• Automatic resetting thermal shutdown
• Input transient protection*
• High/low input voltage shutdown
• Polyurethane conformal coating on PC board
• Power “ON” light
• On/Off switch
  *ISP Series only

Performance Specifications: Isolated and ISP Series
Output: 13.6 VDC (internally adjustable 12.6-14.5) or 24.5 VDC (or specify)
Ripple: 150 mV P-P Regulation: +/- 2% Line/Load Duty Cycle Ratings*: Intermittent - 20 minutes,
max on time,20% duty, Continuous - 24 hours, 100% duty
*Current limit set at approximately 105% of intermittent rating
Idle Current: (including power "on" indicator light) approx. 50 mA
Operating Temp:
Isolated Series: 0-50° C; derate linearly from 100% @ 40° C to 50% @ 50° C
ISP Series: see temperature rating curves (below)
Switching Frequency: 70Khz
Efficiency: 85% - typical.
DC Isolation: Input/Output, Input/Chassis, Output/Chassis):
Isolated Series: 250 VDC
ISP Series: 1,400 VDC

Isolated Series
Model
Input
Voltage
Output
Voltage
Output Amps
Case
Size
Weight
Intermittent
Continuous
Lbs
Kg
12-12-12I
10-16**
13.6
12
8
C-8
6
2.7
12-24-6I
10-16**
24.5
6
4
C-8
6
2.7
12-12-35I
10-16**
13.6
35
20
C-9
12
5.5
12-24-18I
10-16**
24.5
18
10
C-9
12
5.5
48-12-6I
20-56
13.6
6
6
C-7
7
2.7
48-24-3I
20-56
24.5
3
3
C-7
7
2.7
48-12-12I
20-56
13.6
12
8
C-8
6
2.7
48-24-6I
20-56
24.5
6
4
C-8
6
2.7
48-12-18I
20-56
13.6
18
10
C-8
8
3.6
48-24-9I
20-56
24.5
9
5
C-8
8
3.6
48-12-35I
20-56
13.6
35
20
C-9
12
5.5
48-24-18I
20-56
24.5
18
10
C-9
12
5.5
**11.5 VDC minimum start-up voltage, then operates @ 10-16 VDC from 1 amp minimum to full load

ISP Series
Model
Input
voltage
Output
voltage
Output Amps
Case
Size
Weight
Intermittent
Continuous
Lbs
Kg
36-12-6ISP†
18-65
13.6
6
6
C-7
5
2.3
36-24-3ISP
18-65
24.5
3
3
C-7
5
2.3
36-12-18ISP
20-65
13.6
18
10
C-6
8
3.6
36-24-9ISP
20-65
24.5
9
5
C-6
8
3.6
36-12-35ISP*
20-65
13.6
35
20
C-9
12
5.5
72-12-6ISP
42-90
13.6
6
6
C-7
5
2.3
72-24-3ISP
42-90
24.5
3
3
C-7
5
2.3
72-12-18ISP
42-90
13.6
18
10
C-6
8
3.6
72-24-9ISP
42-90
24.5
9
5
C-6
8
3.6
110-12-18ISP
80-140
13.6
18
10
C-6
8
3.6
110-24-9ISP
80-140
24.5
9
5
C-6
8
3.6
† This model EMC and safety CE certified for sales within the European Union.
*Build to order only – 10 unit minimum

ISP Surge Protection
Transient Energy Capability:
36 VDC Input: 140 joules (Watt-Seconds) Peak Current, 2,000 Amps
72 & 110 VDC Input: 100 Joules (Watt-Seconds) Peak Current, 12,000 Amps

Temperature Specifications - ISP Series
Operating Temperature -40° C to +80°C Thermal shutdown @ 85° C Case Temperature

ISP Series Temperature/Amperage Derating Curves



Options
• operation as a battery charger or parallel/ redundant operation (contact factory)
• Other “Special” output voltages available


High vibration mounting kit

The Extreme Vibration Mounting Kit is available to protect NEWMAR power converters from the extreme stresses of shock and vibration when mounted on high–vibration vehicles.

The kit (pictured here) replaces the standard vibration kit provided with the unit and fits into the unit's mounting flange to act as a "super shock absorber" for electronics in high-vibe applications. It is available to fit all NEWMAR units from 2 to 70 lbs. Specify KIT–L for units which weigh 2–15 lbs. and Kit–H for units which weigh 16-70 lbs.