Low Voltage Disconnect | | |
| Low Voltage Disconnect-LVD Discharging batteries beyond a critical low voltage can damage the batteries and/or load, and require a longer recharge interval. A low voltage disconnect prevents this condition. The LVD contains a sense and control circuit housed in a compact, rugged, vinyl-clad aluminum case. It is installed in-line between the battery and the load. The unit continually monitors battery voltage and if it falls below a preset voltage threshold, the load is automatically disconnected. When batteries are recharged past another pre-set voltage the load is reconnected. connect and disconnect points are user adjustable. Models: LVD 12-30, LVD 12-75 (Neg. Ground) LVD 24-20, LVD 24-50 (Neg. Ground) LVD 48-30 (Pos. Ground) For high current model, see PFM-400 |
![]() |
Factory set actuation voltages:
|
12 VDC
|
24 VDC
|
48 VDC
|
|
|
Connect
|
12.2 VDC
|
24.5 VDC
|
49.0VDC
|
|
Disconnect
|
10.4 VDC
|
21.0 VDC
|
42.0 VDC
|
Voltage and Contact Current Ratings:
Indicated By Model Number (i.e., LVD 12-30 = 12 Volts, 30 amps Continuous)
Dimensions (mounted vertically, all models): 5.25” High x 5.25” Wide x 3.5” Deep
Weight: (All models): 1LB.
Operating Temperature: 0-50 °C
Typical LVD Installation

Application notes:
• 1 sec. switch over delay may not be suitable for data transceivers. Instead, use a system where
the battery is floated on output of power supply see Power Pac or IPS or APS.
• Trickle charge current will maintain a back up battery but will not restore a deeply discharged battery.
A separate high current charging source is required.
Specifications
|
ERC Model
|
Amps
|
Size-inches
|
Wieght
|
||||
|
Int.
|
Cont.
|
H
|
W
|
D
|
Lbs
|
Kg
|
|
|
12-15
|
15
|
10
|
2.25
|
2.875
|
4
|
1
|
.5
|
|
24-15
|
15
|
10
|
2.25
|
2.875
|
4
|
1
|
.5
|
|
12-35
|
35
|
30
|
3.875
|
2.875
|
4
|
2
|
.9
|
|
24-35*
|
35
|
30
|
3.875
|
2.875
|
4
|
2
|
.9
|
| *Built to order | |||||||
Typical Trickle Charge Current:
1.5 amps will vary depending on power supply voltage and battery condition.
Optimal Power Supply Voltage:
12 volt systems: 13.4 - 14.0 VDC
24 volt systems: 26.8 - 28.0 VDC
Antenna/Coax Switches
| manual Model: CS-201 Two position switch allows manual selection of one of two antennas with a single radio or one of 2radios with a single antenna. Die cast aluminum case. Power: 1.5 kW peak, 1kW continuous Impedance: 50 ohm Connectors: S0-239/UHF Weight: 1Lb., .5Kg. |
![]() |
| Remote Model: RCS Operates on 12 VDC, single pole, double throw. Permits remote selection of two antennas with a single radio. Power:1Kw. Impedance: 48 ohm Coil Current: 250 m A Connectors: SO-239/UHF Weight: 1 Lb., .5 Kg. |
![]() |
| Microphone Clips All stainless steel. For securing standard VHF microphone when not in use. Lift to release. |
![]() |