
These inverters provide seamless back-up power for AC powered communications equipment from the site’s
48 or 24 VDC battery system. A fast-acting transfer switch ensures voice and data transmissions remain
uninterrupted in the event of a power grid failure or if the site utility power is disconnected for maintenance
and upgrade purposes. Built in a 2RU case adaptable for 19” and 23” rack installations.
Features
• Pure sine wave AC output powers telecom equipment without performance degradation
• Continuous duty rated full output wattage maintained even during extended power outages
• 1000 VA and 2000 VA models available easily cascaded for N+1 redundancy, providing maximum reliability
required by data centers
• Low EMI and RFI interference characteristics
• User-friendly Status and Diagnostic LCD/LED displays
• Utility bypass function with fast load transfer switch
• Remote Power Management optional via RS-232 port
• Optional SNMP card
• Numerous circuit and load protections over-current, over- temp, overload, reverse polarity, high/low battery
voltage
• Form C alarm contacts for monitoring AC “Fault” and “DC Abnormal” conditions
• Adapts for 19” or 23” racks; occupies only 2 RU (3.5”)
• UL and cUL listed
Specifications
|
Model
|
DC Input
|
AC Output
|
||
|
Voltage
|
Amps
|
KVA
|
Watts
|
|
|
48-1000RM
|
40-60
|
25
|
1 KVA
|
800
|
|
48-2000RM
|
40-60
|
50
|
2 KVA
|
1600
|
|
24-1000RM
|
20-30
|
50
|
1 KVA
|
800
|
|
125-1000RM
|
100-150
|
10
|
1 KVA
|
800
|
|
125-2000RM
|
100-150
|
20
|
2 KVA
|
1600
|
|
48-1000IRM*
|
40-60
|
25
|
1 KVA
|
800
|
|
48-2000IRM*
|
40-60
|
50
|
2 KVA
|
1600
|
AC Characteristics
Voltage: 100/110/115/120 VAC (selectable using RS-232 port and additional software); Factory set at 115 VAC
Frequency: 60 Hz. Standard, 50 Hz. Optional
Regulation: +/- 2%
Wave Form: Pure Sine
Outlets Rear Panel:
24-1000RM and 48-1000RM (4 ea.) NEMA 5-15R
48-2000RM (4 ea.) NEMA 5-20R
Total Harmonic Distortion: 6% 120V/100% linear load 4% 120V/100% SPS load
Transfer Time: <4 ms.
Displays
LED: Inverter On, Overload, DC Abnormal, Fault
LCD: Inverter On, Output Voltage and Frequency, Input Voltage, Load Percentage, DC Voltage, System Model,
Internal Environment Temperature, Utility Status, Short Circuit, Over Temperature
Operating Temperature: 0° to 45° C
Cooling: Forced air, front-to-back
Humidity: 0-90% relative humidity
Acoustic Noise: 46 dBA @ 1 M
Alarms
Form C (Dry Contact) terminals (two sets “DC ABNORMAL” and “FAULT”)
Communication Interface
RS-232 port, serial cable included
Protection Features
DC Input Fuse and Breaker, AC Input Breaker, Output Breaker, Short Circuit, Overload, Over
Temperature, Over/Under Output Voltage, Over/Under Input Voltage, Fan Failure Detection
Mechanical
Dimensions: 17.4”W x 3.5”H x 11.6”D
Mounting: 19” or 23” Rack
Weight: 24-1000RM and 48-1000RM 15.4 Lbs., 48-2000RM 17.6 Lbs.
Options
Remote monitor via RS 232 port. SNMP card required.
| Request Evaluation Sample |

