Visit our Product Selection Guide for help choosing the correct product and model for your application.
Hot Swap Rectifiers
150 Watt Rectifiers
550 Watt Rectifiers
1600 Watt Rectifiers, 48V
Rackmount Rectifiers
Power Modules
Integrated w/ built-in battery
Power Function Manager
DC-DC Converters
Rackmount
Mobile Mount
DC-AC Inverters
Rackmount
Mobile Mount
Power Distribution
Circuit Breaker
Fuse
Power Distribution System
Battery Chargers
Wall Mount
12, 24, 32 V; 8-95 Amps
Wall Mount Modular
12, 24 V; 67-100 Amps
Mobile Mount
12, 24 V; 8-35 Amps
Power Plants
DC Power Plants
Rack Accessories
Trays & Shelves
Batteries & Accessories
Battery Modules
Integrators & Isolators
Instruments/Analyzers
Automatic Power Selector
Power Supplies
Mobile Mount
With built-in battery
Enclosure Power Supply
Pole or Wall Mount
Low Voltage Disconnects
Rackmount
Wall Mount
DC Power Conditioners
StartGuard & Nav-Pac

Noise Filters

Voltage Stabilizing Converters

DC Power Stabilizers
12 & 24 Volt Stabilizers
Accessories
Installation
Electrical Installation
Phone Coms
Paging Speakers
Waterproof radio covers
Phase Three Series Battery Chargers

Newmar’s Phase Three “Smart” Battery Chargers wide model range covers battery systems ratings from 14-1000 amp-hours. Selector switch adjusts output voltage for gel-cel, flooded lead acid and AGM battery types; “Smart” circuitry provides three stage charging, bulk, absorption, and float which also provides different charging levels based on temperature of the battery.

Phase Three “Smart” battery charging technology is now available in a wide range of power levels, allowing you to select the right size, features and flexibility you require for virtually any application from providing quick recharge of auxiliary batteries in vehicles parked in the station house, to powering continuous loads and maintaining peak charge in large battery systems in remote communication sites as well as industrial generator and marine applications. These chargers interact with batteries to put them through the optimum three stage charge process which provides for fastest recovery and ideal conditioning, maximizing battery performance and extending battery life.

A selector switch adjusts output voltage to adapt for gel-cell/flooded lead-acid/AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries' ambient temperature. All models are housed in a rugged stainless steel case, and the internal circuitry is polyurethane coated for maximum corrosion resistance.


Features
• “Smart” circuitry provides three stage charging—bulk, absorption, float.
• Wide model range covers battery system ratings from 14-950 amp-hours
• Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum charge/float voltages.
• Multiple isolated output banks; ammeter indicates total output current*.
• Optional sensor adjusts output voltage based on battery temperature (except PT-7).
• Current limiting-prevents damage from overloading.
• Charger status clearly displayed with L.E.D. and/or audible indicators or optional remote panel.
• Use as a power supply; can power loads without a battery in line.
• Built to last—rugged stainless steel case with drip shield and polyurethane coated internal circuitry.
• Numerous Safety and EMC Compliances
• Two year parts and labor warranty

Models
12 Volt
24 Volt
32 Volt
PT-7
PT-24-8
PT-32-25
PT-14
PT-24-13
PT-25
PT-24-20
PT-40
PT-24-40
PT-70A
PT-24-45F
PT-24-60F
PT-24-95F
Detailed specifications below.

Specifications
12 Volt Models
PT-7
PT-14
PT-25
PT-40
PT-70A
Input VAC
(50-60 Hz.)
88-132 or
176-264
85-264
90-132 or
180-264
85-135 or
170-270
90-264
Input Amps @ Full Load
@ 115 VAC
2
2.8
6.5
8.5
12
@ 230 VAC
1
1.4
4
4.3
6
P.F. Rating
>.65
.98@115V
.95@230V
.7
.7
.95@230V
.98@115V
Max Output Amps
@ 115 VAC Input
7
14
25
40
64
@ 230 VAC Input
7
14
25
40
70
Output Banks
2
3
3
3
3
Battery Capacity
Amp-Hours
14-70
28-140
50-250
80-400
140-700
Operating Temp.
Rating Ref.
T-2
T-2
T-2
T-1
T-2
Weight; Lbs./Kg.
3.2/1.5
8/4
8.2/4
12/6
15.2/7
Case Size Ref.
A-1
A-2
A-2
A-3
A-5
Optional Temp
Sensor Model
N/A
TCS-12/24
TCS-12/24
TCS-12/24
TCS-12/24
Remote Panel Model
N/A
RP
RP
RP
RP
Equalize Option
No
Yes
Yes
Yes
Yes
Output Indicator Ref.
M-2
M-1
M-1
M-1
M-1
Compliance Ref.
CG, CE
CG, CE
CG
UL, CG, CE
CE

24 Volt Models
PT-24-8
PT-24-13
PT-24-20
PT-24-40
PT-24-45F
PT-24-60F
PT-24-95F
Input VAC
(50-60 Hz.)
85-264
90-132 or
180-264
85-135 or
170-270
90-264
207-253
207-253
207-253
Input Amps @ Full Load
@ 115 VAC
2.8
6.5
8.5
12
N/A
NA
N/A
@ 230 VAC
1.4
4
4.3
6
8
13
17
P.F. Rating
.95@230V
.98@115V
.7
.7
.95@230V
.98@115V
.7
.7
.7
Max Output Amps
@ 115 VAC Input
8
13
20
37
N/A
NA
N/A
@ 230 VAC Input
8
13
20
40
45
60
95
Output Banks
3
3
3
3
3
3
3
Battery Capacity
Amp-Hours
16-80
26-130
40-200
80-400
90-450
150-600
180-950
Operating Temp.
Rating Ref.
T-2
T-2
T-1
T-2
T-3
T-3
T-3
Weight; Lbs./Kg.
8/4
8.2/4
12/6
15.2/7
12.2/6
34.0/15
34.0/15
Case Size Ref.
A-2
A-2
A-3
A-5
A-4
A-6
A-6
Optional Temp
Sensor Model
TCS-12/24
TCS-12/24
TCS-12/24
TCS-12/24
TP
TP
TP
Remote Panel Model
RP
RP
RP
RP
N/A
N/A
N/A
Equalize Option
Yes
Yes
Yes
Yes
No
No
No
Output Indicator Ref.
M-1
M-1
M-1
M-1
M-3
M-3
M-3
Compliance Ref.
CG, CE
CG
UL, CG, CE
CE
EN, CE
EN, CE
EN, CE

32 Volt
PT-32-25
Input VAC
(50-60 Hz.)
104-126
Input Amps @ Full Load
@ 115 VAC
14
@ 230 VAC
N/A
P.F. Rating
.7
Max Output Amps
@ 115 VAC Input
25
@ 230 VAC Input
N/A
Output Banks
3
Battery Capacity
Amp-Hours
60-300
Operating Temp.
Rating Ref.
T-3
Weight; Lbs./Kg.
15.2/7
Case Size Ref.
A-5
Optional Temp
Sensor Model
TP
Remote Panel Model
N/A
Equalize Option
No
Output Indicator Ref.
M-3
Compliance Ref.
EN, CE

Case Size
Ref
Inches
Centimeters
H
W
D
H
W
D
A-1
10.5
5.0
2.8
26.7
12.7
7.1
A-2
12.5
7.7
4.3
31.8
19.6
10.9
A-3
14.1
9.5
4.0
35.8
24.1
10.2
A-4
15.5
9.7
5.0
39.4
24.6
12.7
A-5
16.7
9.8
6.7
42.4
24.9
17.0
A-6
19.5
12.2
8.2
49.5
40.0
20.8

Temperature Rating References:
T-1
-25˚C to +60˚C; Derate linearly from 100% @ 50˚C to 75% @ 60˚C
T-2
-10˚C to +60˚C; Derate linearly from 100% @ 50˚C to 80% @ 60˚C
T-3
-20˚C to +60˚C; Derate linearly from 100% @ 45˚C to 70% @ 60˚C

Output Indicator References
M-1
Total output ammeter
M-2
Charge/Float L.E.D.
M-3
Total output ammeter and charger status L.E.D.'s/Alarms

Compliance References*
See matrix for applicable models
UL UL 1950 (Per DNB report)
CG USCG CFR 183.410 (Ignition protected)
EN EN 60335-1, EN 60335-2-29
CE Carries the CE Mark
* Numerous other Safety and EMC compliances may also apply. Contact factory if further compliance
  information is required.

Nominal Output Voltages at Gel/Flooded Switch Settings
(Without Temperature Compensation option installed or at 22.2˚C (72˚F) with Temperature
Compensation option installed.)
12 Volt Models
24 Volt Models
32 Volt Model
Charge
Float
Charge
Float
Charge
Float
Setting
@ 50% load
@ .5 amp load
@ 50% load
@ .5 amp load
@ 50% load
@ .5 amp load
Gel-Cell
14.0 VDC
13.6 VDC
28.0 VDC
27.2 VDC
37.3 VDC
36.2 VDC
Flooded/AGM
14.2 VDC
13.4 VDC
28.4 VDC
26.8 VDC
37.8 VDC
35.7 VDC

Typical Charging Curve


Temperature Compensation:
- 5 mV per cell per ˚C. Sensor supplied with 25' cable and plug-in connector

Protection (all models):
Input/Output Fuses, Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield

Remote Panel, Model RP:
LED's indicate charger output stage. Button allows manual reinitialization of three stage charge cycle. Supplied with 25' cable and plug-in connector. Panel dimensions: 3" H x 4.75" W

Optional Accessories


Remote Indicator Panel, Model: RP
(Not available for all models - refer to Specification Matrix above)


DCE - DC Energy Monitor, reads Volts, Amps, Amp Hours


Temperature Compensation Sensor, Model: TCS-12/24 shown
(see Specification Matrix above for applicable sensor depending on charger model)



Request Evaluation Sample