Visit our Product Selection Guide for help choosing the correct product and model for your application.
Hot Swap Rectifiers
150 Watt Rectifiers
550 Watt Rectifiers
1600 Watt Rectifiers, 48V
Rackmount Rectifiers
Power Modules
Integrated w/ built-in battery
Power Function Manager
DC-DC Converters
Rackmount
Mobile Mount
DC-AC Inverters
Rackmount
Mobile Mount
Power Distribution
Circuit Breaker
Fuse
Power Distribution System
Battery Chargers
Wall Mount
12, 24, 32 V; 8-95 Amps
Wall Mount Modular
12, 24 V; 67-100 Amps
Mobile Mount
12, 24 V; 8-35 Amps
Power Plants
DC Power Plants
Rack Accessories
Trays & Shelves
Batteries & Accessories
Battery Modules
Integrators & Isolators
Instruments/Analyzers
Automatic Power Selector
Power Supplies
Mobile Mount
With built-in battery
Enclosure Power Supply
Pole or Wall Mount
Low Voltage Disconnects
Rackmount
Wall Mount
DC Power Conditioners
StartGuard & Nav-Pac

Noise Filters

Voltage Stabilizing Converters

DC Power Stabilizers
12 & 24 Volt Stabilizers
Accessories
Installation
Electrical Installation
Phone Coms
Paging Speakers
Waterproof radio covers
Power Modules
Newmar’s Powering the Network with Power Modules. These versatile Rectifier Modules function as either a power supply or battery chargers for 12, 24 or 48 volt systems with positive, negative or floating ground.
These Versatile Rectifier Modules function as either power supplies or battery chargers for 12, 24 or 48 volt systems; positive, negative or floating ground. They may be employed singly or in combination, enabling the installer to scale the system anywhere from 500 to 10,000 watts per rack. Units may be paralleled for N + 1 redundancy and alarm contacts allow local or remote monitoring. An optional DC quick connect wiring kit allows easy replacement of modules without system shutdown.

Power Modules may be used separately as a power source, or they may be integrated with the Power Function Manager to greatly expand the system capability with other functions such as digital output monitoring, powering multiple loads via circuit breaker distribution and low voltage battery disconnect.


Features
• 12, 24 or 48 volts output; pos., neg. or floating ground
• 115 or 230 VAC, 50-60 Hz input 560 & 1000 watt models
• 230 VAC only 2500 watt models
• 560, 1000 or 2500 watts per module (approx.)
• Built-in oring diode for parallel or N + 1 configuration
• Power supply or battery charger operation (DC UPS system)
• Battery charging options: three-step charging, gel/lead-acid switch, equalization and temperature
  compensation
• Remote shutdown control option via TTL signal (except 2500 watt models)
• Form C alarm contacts
• 19" or 23", flush or 6” forward rackmount


Model
Input Amps
@ Full Load
115/230V
Output
Watts
Weight
VDC
V Out
VDC
V2
Amps
Cont.+
Lbs.
Kg.
PM-12-40
8.5/4.3
13.6
14.3
40
560
12.2
5.5
PM-12-70
16/8
13.6
14.3
70
1000
15.2
6.9
PM-24-20
8.5/4.3
27.2
27.9
20
560
12.2
5.5
PM-24-35
16/8
27.2
27.9
35
1000
15.2
6.9
PM-24-80**
*/22
27.2
80
2000
34
15
PM-48-10
8.5/4.3
54.4
55.1
10
560
12.2
5.5
PM-48-18
16/8
54.4
55.1
18
1000
14.0
6.4
PM-48-50
*/22
54.4
50
2500
34
15
VDC (V out) Measured at output terminal with oring diode
VDC (V2) Measured at direct output terminal
+ For parallel configuration/load sharing derate output 10%
* 230 VAC input only
** in development

Performance Specifications
• Input: 85-135/170-270 VAC (selectable), 47-63 Hz. 560 & 1000 watt models.
  207-253 VAC only 2500 watt models
• Power Factor: 0.7
• Regulation: ± 1% at direct output (V2); ±2% through "oring" diode (V out)
• Ripple: 1% (Typical)
• Efficiency: 80-85% @ full load
• Front panel Output Voltage adjustment pot range: ±10%
• Altitude Range: Full output to 5,000 feet. Derate output current 4% per 1,000 feet to 10,000 feet max.

Design Standards
• UL 1950 / EN 60950 (Safety)
• EN 50082 (Immunity)
• EN 55014 (Conducted)

Mechanical/General
• Anodized aluminum front panel
• Vinyl laminated base and cover
• 19" or 23" Rackmount, brackets provided
• Wallmount via optional brackets
• IEC AC entry module. 6’ power cord with NEMA 5-15 plug, 115 VAC. (560 watt models)
• 6’ power cord with NEMA 6-15 plug, 230 VAC (1,000 watt models)
• 6’ power cord with NEMA 5-20 plug, 115 VAC also supplied (1,000 watt models)
• Hardwire junction box on 2500 watt units, no power cord provided
• 1/4” -20 Output stud (560 watt models)
• Output bus bar (1,000 & 2500 watt models) with 1/4” - 20 studs
• Output "OK" L.E.D.
• Loss-of-output alarm contacts- Form C, plus loss of AC alarm contacts Form C- 2500 watt units only
• Front panel voltage test points

Protection
• Output fuse for reverse polarity
• Current limit
• Input circuit breaker
• Automatic high temp. output power reduction
• Forced air cooling with filter provided

Temperature Rating
560 & 1000 watt models: -40° C to +60° C; Derate linearly from 100% load @ 50°C to 75% @ 60° C
2500 watt models: 0-50°C

Case Size
Inches
Centimeters
H
W*
D
H
W*
D
3.5
17
20.5
13.5
43.2
52.1
*19” and 23” mounting brackets provided

Options
• Three stage charger function with gel/lead-acid selector Model: CFB 560 & 1000 watt units only
• Temperature compensation (for battery charging). All models.
• DC quick connect wiring kit, 560 & 1000 watt Models: QCK-3 (for 2-3 unit PM system),
  QCK-6 (for 4-6 unit PM system), QCK-4 (2500 watt models)
• “Universal” mounting bracket; Model: UMB-PM (500 & 1KW models only)
• Metering, alarms, LVD and distribution breakers (PFM-400 option)


Request Evaluation Sample